Modeling Temperature Impacts on Salmon Survival
Among research goals at the University of California-Davis are the development and application of mathematical models to study water quality impacts on threatened and endangered species....

Evaluation of the Pagosa Springs Geothermal Reservoir and Implications of Potential Additional Reservoir Development
The Town of Pagosa Springs is located 280 miles from Denver on the north bank of the San Juan River in southwest Colorado as shown on the Index Map, Some time before 1920 the first well...

Plate and Frame Membrane Air Stripping
This paper examines utilization of a plate and frame membrane air stripping system for the removal of volatile organic chemicals (VOCs) and radon from a water supply. Previous work explored...

MPOS Become VIPS
The 1991 Intermodal Surface Transportation Efficiency Act made metropolitan planning organizations very important players in transportation decisionmaking. MPOs have been around since...

Different Methods to Compute Pollutant Dispersion Around Buildings
Different methods to approximate the advection terms currently in use are reviewed. Holly-Preismann (HP) cubic interpolation using method of characteristics, Chapeau function (CF) method...

Field Test of Thermal Precompression
A new concept for improvement of soft ground using moderate heating to control post-construction settlement is presented. The long-term creep behavior of a peat is presented based on laboratory...

Coastal Eutrophication and Temperature Variation
A 3-D hydroecological model has been developed to simulate the impact of climate-change-induced daily temperature variation on coastal water quality and eutrophication. Historical daily...

Flocculation Kinetics Using Fe(III) Coagulant to Coagulate Kaolin Clay in Water: Effects of Temperature
Flocculation kinetics using ferric nitrate as a coagulant to coagulate kaolin clay in water was examined using several experimental factors. Both the particle size distribution data obtained...

Thermally Enhanced Bioremediation of a Gasoline-Contaminated Aquifer Using Toluene Oxidizing Bacteria
The combined application of steam injection and vacuum extraction has proved to be very effective for the in situ remediation of a gasoline contaminated aquifer. It is expected that the...

Quantification of the Mechanisms Controlling the Removal Rate of Volatile Contaminants by Air Sparging
Air sparging is a technology for removing dissolved and volatile phase chemicals (VOCs) from the saturated zone. It is used in conjunction with soil vapor extraction (SVE) and sometimes...

Contribution of Waterborne Radon to Home Air Quality
A controlled experiment was performed to explore the contribution of waterborne radon to home air quality and the effect of radon removal from a centralized water system on indoor radon...

Measuring Air Concentration in Flowing Air-Water Mixtures
This paper describes the use of an electrical conductivity probe to determine aeration of a plunge pool by an overfall nappe. The probe was calibrated using an apparatus designed to provide...

Testing Turbine Aeration for Dissolved Oxygen Enhancement
During August of 1993 the Bureau of Reclamation tested turbine aeration for dissolved oxygen (DO) enhancement at Deer Creek Powerplant near Provo, Utah. This test required a variety of...

The Great Lakes Forecasting System: An Overview
The Great Lakes Forecasting System is a full three-dimensional model-based system designed to make regularly scheduled predictions of the physical status of each of the Great Lakes. Due...

GLFSVIEW - GLFS Product Viewing Application
GLFSVIEW is a menu-driven Visual Basic application running under MicroSoft Windows. This application allows quick downloading, browsing, printing and display of two-dimensional data maps...

Short-Term Forecasts for Lake Erie
Short-term forecasts for Lake Erie were generated by coupling a mesoscale atmospheric prediction system with a lake forecast system. The modeling systems used were The Pennsylvania State...

Fate/Transport Modeling and Remediation of Contaminated Plume at Vance Airforce Base
Air Training Command (ATC) at Vance Air Force Base (VAFB) is responsible for implementing the Installation Restoration Program (IRP) according to the Comprehensive Environmental Response,...

Hydro Plant Research Data Acquisition System
The Colton Hydroelectric Development, located on the Raquette River in the northwestern part of New York State, is the site of a two year research project to test the use of heated trashracks...

Air Concentration Measurements in Highly-Turbulent Flow on a Steeply-Sloping Chute
The U.S. Bureau of Reclamation's (Reclamation) stepped spillway overtopping protection research program required air concentration profile data be obtained during testing in a large, 15.2-m-high...

Design and Testing of Two Ice-Preserving Winter Lake Aeration Systems
As part of an effort to achieve ice-preserving lake aeration for winterkill prevention, two non-mixing lake aeration systems were designed and field tested. Each creates a fish refuge...

 

 

 

 